Every member is supported by a calculation
Each member we size is checked against the loading standard in force on the site, and the calculation is produced on request. The structure is in consequence safe and economical in material, and the submission is prepared so that the approving authority can accept it at the first application.
What the appointment covers
Services are taken in whole or in part. A client who needs only one of the items below is welcome to appoint us for that item alone.
Scheme design and framing strategy
The structural arrangement is settled early. The grid, the spans, the framing material and the depth zones are agreed with the architectural layout before it is fixed.
Foundations
We interpret the geotechnical report and design pad, strip, raft or piled foundations, with underpinning and retaining structures where the site requires them.
Reinforced concrete
Slabs, beams, columns and cores are designed and detailed, and the reinforcement drawings and bar bending schedules are issued in a form from which the steel fixer can work directly.
Structural steel
We size the members and design the connections, and issue member and bolt schedules and drawings to a standard the fabricator can take into the workshop.
Masonry and timber
Loadbearing and infill masonry, lintels and reinforced blockwork are designed under this item, as are timber framing, roof structures and floor systems.
Lateral design
We carry out the wind and seismic analysis, select and design the lateral system, and make the drift and stability checks on which it depends.
Existing structures
We appraise the condition of a structure and assess the load it will carry as built. We then design strengthening, remedial works and any openings to be cut into it.
Temporary works
Propping, excavation support and formwork arrangements are designed and reviewed, so that the building is safe during the sequence of construction as well as on completion.
Calculation and certification package
We issue the calculation set, the design statement and the certification which the approving authority requires, under the seal of a licensed professional.
What is issued, and in what form
A structural package comprises general arrangement drawings, reinforcement or fabrication drawings, schedules, and a calculation set bound and indexed so that any member can be traced from the drawing to the sheet on which it was designed.
Where a contractor proposes a change on site, it is assessed against the original calculation and either accepted in writing or refused with the reason given. Verbal approval of a structural change is not given.
Codes applied
In Colombia we apply NSR-10. In the United Kingdom we apply the Eurocodes with the United Kingdom National Annexes. In the United States we apply ASCE 7 for loading, ACI 318 for concrete and the AISC specification for steel. In Trinidad and Tobago we apply the Small Building Code, with British and American standards where the Code is silent.
Seismic and wind parameters are taken from the hazard mapping that governs the site, and the basis of design is stated on the first sheet of the calculation set.
Send the layout and the ground conditions
Tell us where the site is and what you intend to build. We will set out the scope, the programme and the fee before any work begins.